Share
KFF125 Filtrasan
Synthetic flat filter celi far fan coils with support frame in 3mm-diameter drawn rad and wire mesh that supports the FiltraSan™ sanitizing filter in thermobonded staple fabric with a basis weight of 100 g/m² and a thickness of 5-10 mm.
TECHNICAL CHARACTERISTICS AND LIMITS OF USE
- EN ISO 16890:2016 Group ISO COARSE
(ePM1 = 4% – ePM2,5 = 13% – ePM10 = 49%) - Efficiency class (CEN EN779-2012): G2
- Average gravimetrie efficiency: 70%
- Filter fabric basis weight: 100gr/m²
- Thickness: 10 mm
- Maximum operating temperature: 100°C
- Relative humidity: 100%
- lnitial pressure drop: 21 Pa
- Recommended final pressure drop: 250 Pa
- Maximum pressure drop: 400 Pa
- Dust collection capacity: 180 gr/m²
- Recommended frontal velocity: 1,5 m/s
- Reaction to fire (DIN 53438/3): class F1
- NF-F-16-101: M1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY, INNOVATION
- BREEAM: MAN, WST
FILTERING MEDIA
FiltraSan sanitizing antibacterial and anti-mould filtering media – Sanitized® tested and certified
APPLICATIONS
Fan coils, air treatment units.
PRODUCT DISPOSAL
Dispose of the product by separating the metal part from the filtering part. The CER code for disposal of the metal parts 120101. The CER code for disposal of the filtering part is 150202.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
KF100/R
Synthetic flat filter cell far fan coils with U-section galvanised steel support and containment frame and double electrowelded galvanised wire mesh that supports the 10x 10 honeycomb filter fabric.
Read more -
SA10 Mastersan
Flexible hose made of addivated polyolefin resins film with anti-bacterial, antimildew and anti-viral material protection with steel wire helix.
Read more -
DLG
Nozzle diffuser for the treatment of large volumes of air. Nozzle orientable up to 45° in order to give the correct propagation direction on the air injected.
Read more -
DAM02C
Helical-effect diffuser with helically arranged adjustable deflectors with a high induction ratio (mixing capacity) between the injected and the ambient air. Made up of a plate with holes inside which adjustable plastic deflectors are housed.
Read more
KFF125 Filtrasan
Synthetic flat filter celi far fan coils with support frame in 3mm-diameter drawn rad and wire mesh that supports the FiltraSan™ sanitizing filter in thermobonded staple fabric with a basis weight of 100 g/m² and a thickness of 5-10 mm.
TECHNICAL CHARACTERISTICS AND LIMITS OF USE
- EN ISO 16890:2016 Group ISO COARSE
(ePM1 = 4% – ePM2,5 = 13% – ePM10 = 49%) - Efficiency class (CEN EN779-2012): G2
- Average gravimetrie efficiency: 70%
- Filter fabric basis weight: 100gr/m²
- Thickness: 10 mm
- Maximum operating temperature: 100°C
- Relative humidity: 100%
- lnitial pressure drop: 21 Pa
- Recommended final pressure drop: 250 Pa
- Maximum pressure drop: 400 Pa
- Dust collection capacity: 180 gr/m²
- Recommended frontal velocity: 1,5 m/s
- Reaction to fire (DIN 53438/3): class F1
- NF-F-16-101: M1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY, INNOVATION
- BREEAM: MAN, WST
FILTERING MEDIA
FiltraSan sanitizing antibacterial and anti-mould filtering media – Sanitized® tested and certified
APPLICATIONS
Fan coils, air treatment units.
PRODUCT DISPOSAL
Dispose of the product by separating the metal part from the filtering part. The CER code for disposal of the metal parts 120101. The CER code for disposal of the filtering part is 150202.
DOWNLOAD TECHNICAL SHEET >>
Share
Related products
-
DCMC
High-induction circular diffuser with adjustable cones made up of concentric truncated cone profiles. Height adjustable by means of an adjustment screw in order to change the direction of the air jet in relation to the required thermal conditions.
Read more -
DSRQ – DSRSQ
Variable geometry diffuser on 597×597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up of a half-housing in which individually or simultaneously adjustable deflectors are fitted (if required) in order to change the direction of the air jet in relation to the thermal conditions required.
Read more