DCSQ
Circular diffuser with adjustable cones made up of concentric truncated cone profiles on a square panel, suitable for installation on false ceilings with 600x600mm panels. Height adjustable by means of an adjustment screw in order to change the direction of the air jet in relation to the required thermal conditions.
CARATTERISTICHE
• MATERIAL: aluminium and steel
• SURFACE FINISH: epoxy powder coating resistant to impact and abrasion
• COLOUR: RAL white 9010 glossy, 9016 glossy, 9003 mat. On request, coating in nonstandard RAL colours
• FASTENING: by means of screws positioned on the diffuser neck
• INSTALLATION HEIGHT: 2.7 – 6 m
• USE: room cooling and heating
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for suistainable buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN, WST
INSTALLATION
Easy installation, adjustments and maintenance. The intermediate cone is easy to remove by turning the central hollow threaded pin. It is fastened to the ceiling by means of screws on the diffuser neck.
ADJUSTMENT
Central cone in low position: optimal position in cooling conditions in order to have the largest horizontal diffusion radius without creating discomfort in the occupied area in rooms with an ideal height between 3 and 4 m. With this configuration, you have the best pressure drop, velocity and sound level conditions. The maximum temperature difference (DT) between the ambient air and the air flowing from the diffuser to obtain the optimal induction conditions is 12°C.
Central cone in high position: optimal position for particularly high rooms up to 6 m and in heating conditions, as you obtain a vertical throw that resists the convective motion of the ambient air.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
KF100
Synthetic flat filter celi for fan coils with U-section galvanised steel support frame and double electrowelded galvanised wire mesh that supports the FiltraSan™ sanitizing filter in AT100 series thermobonded staple fabric with a basis weight of 100 gr/m² and a thickness of 5-10 mm.
Read more -
KF125
Synthetic flat filter cell tor fan coils with support frame in 3mm-diameter drawn rod and wire mesh that supports the FiltraSan™ sanitizing filter in AT100 series thermobonded polyester staple fibre with a basis weight of 100 g/m² and a thickness of 5-10 mm.
Read more -
DAM01C
Helical-effect diffuser with radially arranged adjustable deflectors with a high induction ratio (mixing capacity) between the injected and the ambient air. Made up of a plate with holes inside which adjustable plastic deflectors are housed suitable for use at high operating temperatures.
Read more -
DAM02C
Helical-effect diffuser with helically arranged adjustable deflectors with a high induction ratio (mixing capacity) between the injected and the ambient air. Made up of a plate with holes inside which adjustable plastic deflectors are housed.
Read more
DCSQ
Circular diffuser with adjustable cones made up of concentric truncated cone profiles on a square panel, suitable for installation on false ceilings with 600x600mm panels. Height adjustable by means of an adjustment screw in order to change the direction of the air jet in relation to the required thermal conditions.
CARATTERISTICHE
• MATERIAL: aluminium and steel
• SURFACE FINISH: epoxy powder coating resistant to impact and abrasion
• COLOUR: RAL white 9010 glossy, 9016 glossy, 9003 mat. On request, coating in nonstandard RAL colours
• FASTENING: by means of screws positioned on the diffuser neck
• INSTALLATION HEIGHT: 2.7 – 6 m
• USE: room cooling and heating
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for suistainable buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN, WST
INSTALLATION
Easy installation, adjustments and maintenance. The intermediate cone is easy to remove by turning the central hollow threaded pin. It is fastened to the ceiling by means of screws on the diffuser neck.
ADJUSTMENT
Central cone in low position: optimal position in cooling conditions in order to have the largest horizontal diffusion radius without creating discomfort in the occupied area in rooms with an ideal height between 3 and 4 m. With this configuration, you have the best pressure drop, velocity and sound level conditions. The maximum temperature difference (DT) between the ambient air and the air flowing from the diffuser to obtain the optimal induction conditions is 12°C.
Central cone in high position: optimal position for particularly high rooms up to 6 m and in heating conditions, as you obtain a vertical throw that resists the convective motion of the ambient air.
DOWNLOAD TECHNICAL SHEET >>
Share
Related products
-
KF125
Synthetic flat filter cell tor fan coils with support frame in 3mm-diameter drawn rod and wire mesh that supports the FiltraSan™ sanitizing filter in AT100 series thermobonded polyester staple fibre with a basis weight of 100 g/m² and a thickness of 5-10 mm.
Read more -
DAM01C
Helical-effect diffuser with radially arranged adjustable deflectors with a high induction ratio (mixing capacity) between the injected and the ambient air. Made up of a plate with holes inside which adjustable plastic deflectors are housed suitable for use at high operating temperatures.
Read more