AL
Flexible pipe made with AL/PET/AL (aluminium/polyester/aluminium) wall and steel wire helix.
SPECIFICATIONS
- COLOUR: Aluminium
- LENGTHS: from 10 m standard
- PRODUCTION DIAMETERS: from 82 to 508 mm
- WORKING TEMPERATURE: -30°0 /+140°0 (+180°0 peak)
- CURVATURE RADIUS: 0,6 x ø
- AIR SPEED:: max 32m/sec
- PRESSURE: max 250mm ca
- FIRE REACTION:
CLASS IT: Class 1 (D.M. 26/06/84)
Omologation nr.: RE1205C20D100007
CLASS EU: Class B-s1, d0 (EN 13823:2010)
CLASS FR: Class M0 (NF P 92-507:2004)
MED/3.18f – (2014/90/UE) – Surface materials and floor coverings with low flame-spread characteristics:
f) Combustible ducts membrane
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable
buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN, WST
CERTIFICATIONS
Fire reaction. Suitable for building air distribution systems.
APPLICATIONS
Air Conditioning. Ventilation.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
KF100
Synthetic flat filter celi for fan coils with U-section galvanised steel support frame and double electrowelded galvanised wire mesh that supports the FiltraSan™ sanitizing filter in AT100 series thermobonded staple fabric with a basis weight of 100 gr/m² and a thickness of 5-10 mm.
Read more -
KF125/R
Synthetic flat filter cell far fan coils with support and containment frame in 3mm-diameter drawn rod and double electrowelded galvanised steel wire mesh that supports the 10×10 honeycomb filter fabric.
Read more -
AL/SA MASTERSAN
Flexible hose made with AL (aluminium) wall coupled to addivated polyolefin resins film with anti-bacterial, anti-mildew and anti-viral material protection. Inner helix made of steel wire.
The set of materials for the construction of the flexible hose does not provide for the usage of chemical agents, stickers or adhesives.
Read more -
AC
Light flexible hose made of polyester fabric coated with addivated polyolefin resins and steel wire helix.
Read more
AL
Flexible pipe made with AL/PET/AL (aluminium/polyester/aluminium) wall and steel wire helix.
SPECIFICATIONS
- COLOUR: Aluminium
- LENGTHS: from 10 m standard
- PRODUCTION DIAMETERS: from 82 to 508 mm
- WORKING TEMPERATURE: -30°0 /+140°0 (+180°0 peak)
- CURVATURE RADIUS: 0,6 x ø
- AIR SPEED:: max 32m/sec
- PRESSURE: max 250mm ca
- FIRE REACTION:
CLASS IT: Class 1 (D.M. 26/06/84)
Omologation nr.: RE1205C20D100007
CLASS EU: Class B-s1, d0 (EN 13823:2010)
CLASS FR: Class M0 (NF P 92-507:2004)
MED/3.18f – (2014/90/UE) – Surface materials and floor coverings with low flame-spread characteristics:
f) Combustible ducts membrane
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable
buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN, WST
CERTIFICATIONS
Fire reaction. Suitable for building air distribution systems.
APPLICATIONS
Air Conditioning. Ventilation.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
DCSC
Circular diffuser with adjustable cones made up of concentric truncated cone profiles, adjustable in height by means of a screw in order to change the direction of the air jet in relation to the required
Read more -
DMU
Diffuser with individually adjustable micro nozzles with high output velocity and low sound in order to obtain extensive penetration depths of the room to be air conditioned.
Read more