Share
DCSQ THERM
Circular diffuser with adjustable cones made up of concentric truncated cone profiles on a square panel, suitable for installation on false ceilings with 600x600mm panels. The adjustment by means of a thermostatic spring system allows to independently change the position of the cones based on the temperature of the air flow introduced.
CARATTERISTICHE
• MATERIAL: aluminium and steel
• SURFACE FINISH: epoxy powder coating resistant to impact and abrasion
• COLOUR: RAL white 9010 glossy, 9016 glossy, 9003 mat. On request, coating in nonstandard RAL colours
• FASTENING: by means of screws positioned on the diffuser neck
• INSTALLATION HEIGHT: 2.7 – 6 m
• USE: room cooling and heating
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for suistainable buildings:
- LEED: IP, EA, MR, EQ
- WELL: THERMAL COMFORT, MATERIALS, COMMUNITY
- BREEAM: MAN, HEA, WST
INSTALLATION
Easy installation, adjustments and maintenance. The intermediate cone is easy to remove by turning the central hollow threaded pin. It is fastened to the ceiling by means of screws on the diffuser neck.
ADJUSTMENT
Central cone in low position: optimal position in cooling conditions in order to have the largest horizontal diffusion radius without creating discomfort in the occupied area in rooms with an ideal height between 3 and 4 m. With this configuration, you have the best pressure drop, velocity and sound level conditions. The maximum temperature difference (DT) between the ambient air and the air flowing from the diffuser to obtain the optimal induction conditions is 12°C.
Central cone in high position: optimal position for particularly high rooms up to 6 m and in heating conditions, as you obtain a vertical throw that resists the convective motion of the ambient air.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
DCMC
High-induction circular diffuser with adjustable cones made up of concentric truncated cone profiles. Height adjustable by means of an adjustment screw in order to change the direction of the air jet in relation to the required thermal conditions.
Read more -
DCSC
Circular diffuser with adjustable cones made up of concentric truncated cone profiles, adjustable in height by means of a screw in order to change the direction of the air jet in relation to the required
Read more -
DSRQ – DSRSQ
Variable geometry diffuser on 597×597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up of a half-housing in which individually or simultaneously adjustable deflectors are fitted (if required) in order to change the direction of the air jet in relation to the thermal conditions required.
Read more -
DMU
Diffuser with individually adjustable micro nozzles with high output velocity and low sound in order to obtain extensive penetration depths of the room to be air conditioned.
Read more
DCSQ THERM
Circular diffuser with adjustable cones made up of concentric truncated cone profiles on a square panel, suitable for installation on false ceilings with 600x600mm panels. The adjustment by means of a thermostatic spring system allows to independently change the position of the cones based on the temperature of the air flow introduced.
CARATTERISTICHE
• MATERIAL: aluminium and steel
• SURFACE FINISH: epoxy powder coating resistant to impact and abrasion
• COLOUR: RAL white 9010 glossy, 9016 glossy, 9003 mat. On request, coating in nonstandard RAL colours
• FASTENING: by means of screws positioned on the diffuser neck
• INSTALLATION HEIGHT: 2.7 – 6 m
• USE: room cooling and heating
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for suistainable buildings:
- LEED: IP, EA, MR, EQ
- WELL: THERMAL COMFORT, MATERIALS, COMMUNITY
- BREEAM: MAN, HEA, WST
INSTALLATION
Easy installation, adjustments and maintenance. The intermediate cone is easy to remove by turning the central hollow threaded pin. It is fastened to the ceiling by means of screws on the diffuser neck.
ADJUSTMENT
Central cone in low position: optimal position in cooling conditions in order to have the largest horizontal diffusion radius without creating discomfort in the occupied area in rooms with an ideal height between 3 and 4 m. With this configuration, you have the best pressure drop, velocity and sound level conditions. The maximum temperature difference (DT) between the ambient air and the air flowing from the diffuser to obtain the optimal induction conditions is 12°C.
Central cone in high position: optimal position for particularly high rooms up to 6 m and in heating conditions, as you obtain a vertical throw that resists the convective motion of the ambient air.
DOWNLOAD TECHNICAL SHEET >>
Share
Related products
-
AR10 THERM MASTERSAN
Flexible hose made of addivated polyolefin resins film reinforced with polyester mesh with anti-bacterial, anti-mildew and anti-viral material protection with steel wire helix. Thermo-insulating covering in polyester fibre (thickness 25mm/16kg/m3), outer aluminized film protection (flame retardant).
Read more -
DAM31
Helical-effect diffuser with helically arranged adjustable deflectors with a high induction ratio (mixing capacity) between the injected and the ambient air. Made up of a plate with holes inside which adjustable plastic deflectors are housed.
Read more