DCSC
Circular diffuser with adjustable cones made up of concentric truncated cone profiles, adjustable in height by means of a screw in order to change the direction of the air jet in relation to the required
thermal conditions.
The internal cone is closed with a flat panel that gives the diffuser a pleasant aesthetic appearance without penalizing the functional specifications.
SPECIFICATIONS
• MATERIAL: aluminium and steel
• SURFACE FINISH: epoxy powder coating resistant to impact and abrasion
• COLOUR: RAL white 9010 glossy, 9016 glossy, 9003 mat. On request, coating in nonstandard RAL colours
• FASTENING: by means of screws positioned on the diffuser neck
• INSTALLATION HEIGHT: 2.7 – 6 m
• USE: room cooling and heating
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for suistainable buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN, WST
INSTALLATION
Easy installation, adjustments and maintenance. The intermediate cone is easy to remove by turning the central hollow threaded pin. It is fastened to the ceiling by means of screws on the diffuser neck.
ADJUSTMENT
Central cone in low position: optimal position in cooling conditions in order to have the largest horizontal diffusion radius without creating discomfort in the occupied area in rooms with an ideal height between 3 and 4 m. With this configuration, you have the best pressure drop, velocity and sound level conditions. The maximum temperature difference (DT) between the ambient air and the air flowing from the diffuser to obtain the optimal induction conditions is 12°C.
Central cone in high position: optimal position for particularly high rooms up to 6 m and in heating conditions, as you obtain a vertical throw that resists the convective motion of the ambient air.
DOWNLOAD TECHNICAL SHEET >>
Related products
-

DAM21R
Linear throw diffuser on rectangular panel with orthogonally arranged adjustable deflectors with a high induction ratio (mixing capacity) between the injected and the ambient air. Made up of a plate with holes inside which adjustable plastic deflectors are housed.
Read more -

DFL-A
Slotted linear diffuser with adjustable aluminium deflectors with a high induction ratio (mixing capacity) between the injected and the ambient air. Constructed of coupled aluminium profiles to obtain multiple slots inside which adjustable aluminium deflectors are housed. The flow of the air injected can be oriented clockwise, anticlockwise or alternating by changing the position of the deflectors.
Read more -

SER02
Collection damper suitable for installation upstream of the galvanised steel circular diffusers complete with opening/closing mechanism.
Read more -

P01L
Plenum with side outlet for circular diffusers with adjustable cones and for variable geometry diffusers.
Read more
DCSC
Circular diffuser with adjustable cones made up of concentric truncated cone profiles, adjustable in height by means of a screw in order to change the direction of the air jet in relation to the required
thermal conditions.
The internal cone is closed with a flat panel that gives the diffuser a pleasant aesthetic appearance without penalizing the functional specifications.
SPECIFICATIONS
• MATERIAL: aluminium and steel
• SURFACE FINISH: epoxy powder coating resistant to impact and abrasion
• COLOUR: RAL white 9010 glossy, 9016 glossy, 9003 mat. On request, coating in nonstandard RAL colours
• FASTENING: by means of screws positioned on the diffuser neck
• INSTALLATION HEIGHT: 2.7 – 6 m
• USE: room cooling and heating
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for suistainable buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN, WST
INSTALLATION
Easy installation, adjustments and maintenance. The intermediate cone is easy to remove by turning the central hollow threaded pin. It is fastened to the ceiling by means of screws on the diffuser neck.
ADJUSTMENT
Central cone in low position: optimal position in cooling conditions in order to have the largest horizontal diffusion radius without creating discomfort in the occupied area in rooms with an ideal height between 3 and 4 m. With this configuration, you have the best pressure drop, velocity and sound level conditions. The maximum temperature difference (DT) between the ambient air and the air flowing from the diffuser to obtain the optimal induction conditions is 12°C.
Central cone in high position: optimal position for particularly high rooms up to 6 m and in heating conditions, as you obtain a vertical throw that resists the convective motion of the ambient air.
DOWNLOAD TECHNICAL SHEET >>
Related products
-

VMA
Steel ventilation valve diffuser far extraction. The air fio w rate is adjusted by screwing (reducing the flow rate) or unscrewing (increasing the flow rate) the centrai disc.
Read more -

PS01L
Plenum with a protective film with antibacterial and antimycotic action and side outlet for circular diffusers with adjustable cones and for variable geometry diffusers.
Read more