logo

Share

Share on facebook
Share on linkedin
Share on twitter

DCMC THERM

High-induction circular diffuser with adjustable cones made up of concentric truncated cone profiles. The adjustment by means of a thermostatic spring system allows to independently change the position of the cones based on the temperature of the air flow introduced.

  • INSTALLATION HEIGHT: 2.7 – 6 m
  • USE: room cooling and heating

 

SPECIFICTIONS

MATERIAL: Aluminium and steel
SURFACE FINISH: epoxy powder coating resistant to impact and abrasion
COLOUR: RAL white 9010 glossy, 9016 glossy, 9003 mat. On request, coating in nonstandard RAL colours
FASTENING: by means of screws positioned on the diffuser neck

 

GREEN BUILDING

Contribute to obtain the credits of the major international rating systems for suistainable buildings:

  • LEED: IP, EA, MR, EQ
  • WELL: THERMAL COMFORT, MATERIALS, COMMUNITY
  • BREEAM: MAN, HEA, WST

Green Building Completo 2

 

INSTALLATION

Easy installation, adjustments and maintenance. The intermediate cones are easy to remove by turning the central hollow threaded pin. The damper fitted at the top of the diffuser is adjusted by acting on the adjustment screw through the hole in the threaded bar of the diffuser.
It is fastened to the ceiling by means of screws on the diffuser neck.

 

REGOLAZIONE

Central cone in low position: optimal position in cooling conditions in order to have the largest horizontal diffusion radius without creating discomfort in the occupied area in rooms with an ideal height between 3 and 4 m. With this configuration, you have the best pressure drop, velocity and sound level conditions. The maximum temperature difference (Dl) between the ambient air and the air flowing from the diffuser to obtain the optimal induction conditions is 12°C.
Central cone in high position: optimal position for particularly high rooms up to 6 m and in heating conditions, as you obtain a vertical throw that resists the convective motion of the
ambient air.

DOWNLOAD TECHNICAL SHEET >>

DCMC THERM

High-induction circular diffuser with adjustable cones made up of concentric truncated cone profiles. The adjustment by means of a thermostatic spring system allows to independently change the position of the cones based on the temperature of the air flow introduced.

  • INSTALLATION HEIGHT: 2.7 – 6 m
  • USE: room cooling and heating

 

SPECIFICTIONS

MATERIAL: Aluminium and steel
SURFACE FINISH: epoxy powder coating resistant to impact and abrasion
COLOUR: RAL white 9010 glossy, 9016 glossy, 9003 mat. On request, coating in nonstandard RAL colours
FASTENING: by means of screws positioned on the diffuser neck

 

GREEN BUILDING

Contribute to obtain the credits of the major international rating systems for suistainable buildings:

  • LEED: IP, EA, MR, EQ
  • WELL: THERMAL COMFORT, MATERIALS, COMMUNITY
  • BREEAM: MAN, HEA, WST

Green Building Completo 2

 

INSTALLATION

Easy installation, adjustments and maintenance. The intermediate cones are easy to remove by turning the central hollow threaded pin. The damper fitted at the top of the diffuser is adjusted by acting on the adjustment screw through the hole in the threaded bar of the diffuser.
It is fastened to the ceiling by means of screws on the diffuser neck.

 

REGOLAZIONE

Central cone in low position: optimal position in cooling conditions in order to have the largest horizontal diffusion radius without creating discomfort in the occupied area in rooms with an ideal height between 3 and 4 m. With this configuration, you have the best pressure drop, velocity and sound level conditions. The maximum temperature difference (Dl) between the ambient air and the air flowing from the diffuser to obtain the optimal induction conditions is 12°C.
Central cone in high position: optimal position for particularly high rooms up to 6 m and in heating conditions, as you obtain a vertical throw that resists the convective motion of the
ambient air.

DOWNLOAD TECHNICAL SHEET >>

Share

Share on facebook
Share on linkedin
Share on twitter

UNE 23723-90

NF P 92-507 3.1.2

NF P 92-507:2004