AC THERM
Flexible hose made of polyester fabric coated with additivated polyolefin resins and steel wire helix. Thermo-insulating covering in polyester fibre (th. 25mm/16kg/m3). Outer anti-steam protection in additivated polyolefin resin.
Insulation:
- 25mm / 16kg/m3 – standard
- 50mm / 16kg/m3 – on request
Thermal resistivity at 20°C
- R = 0,58m2K/W (UNI EN 12664:2002)
SPECIFICATIONS
- COLOUR: Black, Green
- LENGTHS: from 10m standard
- PRODUCTION DIAMETERS: from 80 to 610mm
- WORKING TEMPERATURE: -20°C /+90°C (+110°C peaks)
- CURVATURE RADIUS: 0,8-1,5 x ø
- AIR SPEED: max 32m/sec
- PRESSURE: max 250mm wc
- FIRE REACTION:
CLASS IT: Class 1 (D.M. 26/06/84)
Omologation nr.: RE1205C20CD100004
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable
buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN, ENE, WST
CERTIFICATIONS
Fire reaction, Heat and sound absorption.
APPLICATIONS
Air conditioning, Single and double-flow mechanical ventilation, Reduction of condensation and heat dispersion.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
KC35
Synthetic flat filter celi tor fan coils with U-section galvanised steel frame and double electrowelded galvanised wire mesh that supports the filter fabric in thermobonded synthetic polyester staple fibre impregnateci with AC CARBON series active carbons with a basis weight of 200 g/m² and a thickness of 5-10 mm.
Read more -
AL/SA MASTERSAN
Flexible hose made with AL (aluminium) wall coupled to addivated polyolefin resins film with anti-bacterial, anti-mildew and anti-viral material protection. Inner helix made of steel wire.
The set of materials for the construction of the flexible hose does not provide for the usage of chemical agents, stickers or adhesives.
Read more -
SA10 THERM Mastersan
Flexible hose made of addivated polyolefin resins film with anti-bacterial, antimildew and anti-viral material protection with steel wire helix. Thermoinsulating covering in polyester fibre (thickness 25mm/16kg/m3). Outer aluminized film protection (flame retardant).
Read more -
DSR – DSRS
Variable geometry diffuser developped for rooms with high ceilings where a long throw and a high induction ratio are required. Made up of a housing in which individually or simultaneously adjustable deflectors are fitted (if required) in order to change the direction of the air jet in relation to the thermal conditions required.
Read more
AC THERM
Flexible hose made of polyester fabric coated with additivated polyolefin resins and steel wire helix. Thermo-insulating covering in polyester fibre (th. 25mm/16kg/m3). Outer anti-steam protection in additivated polyolefin resin.
Insulation:
- 25mm / 16kg/m3 – standard
- 50mm / 16kg/m3 – on request
Thermal resistivity at 20°C
- R = 0,58m2K/W (UNI EN 12664:2002)
SPECIFICATIONS
- COLOUR: Black, Green
- LENGTHS: from 10m standard
- PRODUCTION DIAMETERS: from 80 to 610mm
- WORKING TEMPERATURE: -20°C /+90°C (+110°C peaks)
- CURVATURE RADIUS: 0,8-1,5 x ø
- AIR SPEED: max 32m/sec
- PRESSURE: max 250mm wc
- FIRE REACTION:
CLASS IT: Class 1 (D.M. 26/06/84)
Omologation nr.: RE1205C20CD100004
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable
buildings:
- LEED: IP, EA, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN, ENE, WST
CERTIFICATIONS
Fire reaction, Heat and sound absorption.
APPLICATIONS
Air conditioning, Single and double-flow mechanical ventilation, Reduction of condensation and heat dispersion.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
AR10 THERM MASTERSAN
Flexible hose made of addivated polyolefin resins film reinforced with polyester mesh with anti-bacterial, anti-mildew and anti-viral material protection with steel wire helix. Thermo-insulating covering in polyester fibre (thickness 25mm/16kg/m3), outer aluminized film protection (flame retardant).
Read more -
DCMC
High-induction circular diffuser with adjustable cones made up of concentric truncated cone profiles. Height adjustable by means of an adjustment screw in order to change the direction of the air jet in relation to the required thermal conditions.
Read more