TECHNICAL CHARACTERISTICS AND LIMITS OF USE
- EN ISO 16890:2016 Group ISO ePM10 75%
- Efficiency class (CEN EN779): M6
- Average colorimetric efficiency: 60-80 %
- MERV: 11
- Maximum operating temperature: 80°C
- Relative humidity: 100 %
- Initial pressure drop: 100Pa
- Recommended final pressure drop: 450Pa
- Maximum flow rate: 1.3 times the nominai flow rate
- Recommended filtering velocity: 0,065 m/s
- Reaction to fire (DIN 53438/3): Class F1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: IP, EA, MR
- WELL: AIR, MATERIALS, COMMUNITY
- BREEAM: MAN, WST
FILTERING MEDIA
The filtering media in fireproof and water-repellent micro glass fibre paper is pleated and uniformly spaced out with thermoplastic separators. This configuration allows obtaining.
APPLICATIONS
Filtration in air treatment units, filtration in painting plants, prefiltration of ab solute filters.
PRODUCT DISPOSAL
As the product is entirely made of plastic, it can be disposed of in one single solution. The CER code for disposal is 150202.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
KF100
Synthetic flat filter celi for fan coils with U-section galvanised steel support frame and double electrowelded galvanised wire mesh that supports the FiltraSan™ sanitizing filter in AT100 series thermobonded staple fabric with a basis weight of 100 gr/m² and a thickness of 5-10 mm.
Read more -
KF125/R
Synthetic flat filter cell far fan coils with support and containment frame in 3mm-diameter drawn rod and double electrowelded galvanised steel wire mesh that supports the 10×10 honeycomb filter fabric.
Read more -
SA10 THERM Mastersan
Flexible hose made of addivated polyolefin resins film with anti-bacterial, antimildew and anti-viral material protection with steel wire helix. Thermoinsulating covering in polyester fibre (thickness 25mm/16kg/m3). Outer aluminized film protection (flame retardant).
Read more -
DAM31
Helical-effect diffuser with helically arranged adjustable deflectors with a high induction ratio (mixing capacity) between the injected and the ambient air. Made up of a plate with holes inside which adjustable plastic deflectors are housed.
Read more
GLASS-PLEAT 16GP
Rigid pocket filters with high-resistance moulded polypropylene structure and filter medium in fireproof and water-repellent pleated micro glass fibre paper. Efficiency class M6.
TECHNICAL CHARACTERISTICS AND LIMITS OF USE
- EN ISO 16890:2016 Group ISO ePM10 75%
- Efficiency class (CEN EN779): M6
- Average colorimetric efficiency: 60-80 %
- MERV: 11
- Maximum operating temperature: 80°C
- Relative humidity: 100 %
- Initial pressure drop: 100Pa
- Recommended final pressure drop: 450Pa
- Maximum flow rate: 1.3 times the nominai flow rate
- Recommended filtering velocity: 0,065 m/s
- Reaction to fire (DIN 53438/3): Class F1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: IP, EA, MR
- WELL: AIR, MATERIALS, COMMUNITY
- BREEAM: MAN, WST
FILTERING MEDIA
The filtering media in fireproof and water-repellent micro glass fibre paper is pleated and uniformly spaced out with thermoplastic separators. This configuration allows obtaining.
APPLICATIONS
Filtration in air treatment units, filtration in painting plants, prefiltration of ab solute filters.
PRODUCT DISPOSAL
As the product is entirely made of plastic, it can be disposed of in one single solution. The CER code for disposal is 150202.
DOWNLOAD TECHNICAL SHEET >>
Share
Related products
-
SA10/ESP Mastersan
Flexible hose produced with exclusive technology by TECNICA SRL.
Read more -
DSR – DSRS
Variable geometry diffuser developped for rooms with high ceilings where a long throw and a high induction ratio are required. Made up of a housing in which individually or simultaneously adjustable deflectors are fitted (if required) in order to change the direction of the air jet in relation to the thermal conditions required.