Share
AT200 e AT/BA200
AT200: Roll of filtering media in thermobonded syn thetic polyester staple fibre with a basis weight of 200 g/m²• Efficiency class G4.
AT/BA200: Roll of filtering media in thermobonded syn thetic polyester staple fibre (white/light blue) with a basis weight of 200 g/m² . Efficiency class G3.
TECHNICAL CHARACTERISTICS AND LIMITS OF USE AT200
- Efficiency class (CEN EN779-2012): G4
- Average gravimetric efficiency: 90%
- Filter fabric basis weight: 200gr/m²
- Thickness: 20-22 mm
- Maximum operating temperature: 100°C
- Relative humidity: 100%
- Initial pressure drop: 43 Pa
- Recommended final pressure drop: 250 Pa
- Maximum pressure drop: 400 Pa
- Dust collection capacity: 351 gr/m²
- Recommended frontal velocity: 1,5 m/s
- Reaction to fire (DIN53438/3): class F1
- NF-F-16-101 M1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: IP, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN
CARATTERISTICHE AT/BA200
- Efficiency class (CEN EN779-2012): G3
- Average gravimetric efficiency: 87%
- EN ISO 16890:2016 Group ISO ePM10 50%
- Filter fabric basis weight: 200gr/m²
- Thickness: 18-20 mm
- Maximum operating temperature: 100°C
- Relative humidity: 100%
- Initial pressure drop: 31 Pa
- Recommended final pressure drop: 250 Pa
- Maximum pressure drop: 400 Pa
- Dust collection capacity: 460 gr/m²
- Recommended frontal velocity: 1,5 m/s
- Reaction to fire (DIN53438/3): class F1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: IP, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN
APPLICAZIONI AT200
Air treatment units, prefiltration in high-efficiency filters.
APPLICAZIONI AT/BA200
Air treatment units, prefiltration in high-efficiency filters.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
KF125/R
Synthetic flat filter cell far fan coils with support and containment frame in 3mm-diameter drawn rod and double electrowelded galvanised steel wire mesh that supports the 10×10 honeycomb filter fabric.
Read more -
KC35
Synthetic flat filter celi tor fan coils with U-section galvanised steel frame and double electrowelded galvanised wire mesh that supports the filter fabric in thermobonded synthetic polyester staple fibre impregnateci with AC CARBON series active carbons with a basis weight of 200 g/m² and a thickness of 5-10 mm.
Read more -
AR10 THERM MASTERSAN
Flexible hose made of addivated polyolefin resins film reinforced with polyester mesh with anti-bacterial, anti-mildew and anti-viral material protection with steel wire helix. Thermo-insulating covering in polyester fibre (thickness 25mm/16kg/m3), outer aluminized film protection (flame retardant).
Read more -
DSR – DSRS
Variable geometry diffuser developped for rooms with high ceilings where a long throw and a high induction ratio are required. Made up of a housing in which individually or simultaneously adjustable deflectors are fitted (if required) in order to change the direction of the air jet in relation to the thermal conditions required.
Read more
AT200 e AT/BA200
AT200: Roll of filtering media in thermobonded syn thetic polyester staple fibre with a basis weight of 200 g/m²• Efficiency class G4.
AT/BA200: Roll of filtering media in thermobonded syn thetic polyester staple fibre (white/light blue) with a basis weight of 200 g/m² . Efficiency class G3.
TECHNICAL CHARACTERISTICS AND LIMITS OF USE AT200
- Efficiency class (CEN EN779-2012): G4
- Average gravimetric efficiency: 90%
- Filter fabric basis weight: 200gr/m²
- Thickness: 20-22 mm
- Maximum operating temperature: 100°C
- Relative humidity: 100%
- Initial pressure drop: 43 Pa
- Recommended final pressure drop: 250 Pa
- Maximum pressure drop: 400 Pa
- Dust collection capacity: 351 gr/m²
- Recommended frontal velocity: 1,5 m/s
- Reaction to fire (DIN53438/3): class F1
- NF-F-16-101 M1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: IP, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN
CARATTERISTICHE AT/BA200
- Efficiency class (CEN EN779-2012): G3
- Average gravimetric efficiency: 87%
- EN ISO 16890:2016 Group ISO ePM10 50%
- Filter fabric basis weight: 200gr/m²
- Thickness: 18-20 mm
- Maximum operating temperature: 100°C
- Relative humidity: 100%
- Initial pressure drop: 31 Pa
- Recommended final pressure drop: 250 Pa
- Maximum pressure drop: 400 Pa
- Dust collection capacity: 460 gr/m²
- Recommended frontal velocity: 1,5 m/s
- Reaction to fire (DIN53438/3): class F1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: IP, MR
- WELL: MATERIALS, COMMUNITY
- BREEAM: MAN
APPLICAZIONI AT200
Air treatment units, prefiltration in high-efficiency filters.
APPLICAZIONI AT/BA200
Air treatment units, prefiltration in high-efficiency filters.
DOWNLOAD TECHNICAL SHEET >>
Share
Related products
-
KF100
Synthetic flat filter celi for fan coils with U-section galvanised steel support frame and double electrowelded galvanised wire mesh that supports the FiltraSan™ sanitizing filter in AT100 series thermobonded staple fabric with a basis weight of 100 gr/m² and a thickness of 5-10 mm.
Read more -
SA10/ESP SLEEVE Mastersan
Insulating sleeve produced with exclusive technology by TECNICA SRL.
Read more