M90/FV
Flexible hose made of fibreglass fabric, PVC coated on both sides, embedded steel wire helix. This special execution allows the usage in every suction and ventilation installations, even with moving parts.
SPECIFICATIONS
- COLOUR: Black
- LENGTHS: 1 O m standard (up to 20 m on request)
- FIRE REACTION: Class M1 (NF P92 503), class 1 (D.M. 26/06/84 – D.M. 03/01/01)
- OPERATING TEMPERATURE: -20°C to +90°C (+ 120°c peak)
- CURVATURE RADIUS: R = 0.7 x Ø
- AXIAL COMPRESSIBILITY: 8:1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: MR
- WELL: MATERIALS
APPLICATIONS
Suction of fumes, gases and vapours. Ventilation and aeration. Naval and civil air-conditioning.
MAINTENANCE
Periodically check the state of wear of the hose and immediately replace it if damaged or broken. Pay maximum attention to the duct operating temperatures.
DOWNLOAD TECHNICAL SHEET >>
Related products
-
PVC-FLEX Superelastic
Flexible hose made of two PVC sheets (black internal layer and transparent external layer) with reinforcement spiral between the two layers. Internal plastic-coated steel helix. Very lightweight and extremely flexible hose with excellent resistance to vacuum.
Read more -
P150/PU (ESTER BASE)
Flexible hose made of a polyurethane (PU-ester) sheet(th. 1,10 mm) and embedded copper-plated steel wire helix.
Read more -
P70/PU (ESTER BASE)
Flexible hose made of a polyurethane (PU-ester) sheet (th. 0,45 mm) and embedded copper-plated steel wire helix with thick pitch.
Read more -
AC
Light flexible hose made of polyester fabric coated with addivated polyolefin resins and steel wire helix.
Read more
M90/FV
Flexible hose made of fibreglass fabric, PVC coated on both sides, embedded steel wire helix. This special execution allows the usage in every suction and ventilation installations, even with moving parts.
SPECIFICATIONS
- COLOUR: Black
- LENGTHS: 1 O m standard (up to 20 m on request)
- FIRE REACTION: Class M1 (NF P92 503), class 1 (D.M. 26/06/84 – D.M. 03/01/01)
- OPERATING TEMPERATURE: -20°C to +90°C (+ 120°c peak)
- CURVATURE RADIUS: R = 0.7 x Ø
- AXIAL COMPRESSIBILITY: 8:1
GREEN BUILDING
Contribute to obtain the credits of the major international rating systems for sustainable buildings:
- LEED: MR
- WELL: MATERIALS
APPLICATIONS
Suction of fumes, gases and vapours. Ventilation and aeration. Naval and civil air-conditioning.
MAINTENANCE
Periodically check the state of wear of the hose and immediately replace it if damaged or broken. Pay maximum attention to the duct operating temperatures.